CAPA
Corrective and Preventive Action
CAPA (Corrective and Preventive Action) is 의료기기 제조 및 운영에서 품질 문제를 조사, 시정 및 예방하기 위한 체계적인 접근 방식.
Complete Guide to CAPA
CAPA (Corrective and Preventive Action) is a fundamental quality management system process used to systematically investigate and eliminate the root causes of quality issues, nonconformances, and potential problems in medical device manufacturing and operations.
Definition and purpose in quality systems:
CAPA is a proactive quality management tool that ensures organizations learn from mistakes, prevent recurrence, and continuously improve their processes. It forms the backbone of a robust Quality Management System (QMS) by addressing both existing problems (corrective action) and potential problems (preventive action).
Corrective vs Preventive Action:
- Corrective Action - Addresses existing nonconformances or problems that have already occurred. The focus is on identifying root causes and implementing solutions to prevent recurrence.
- Preventive Action - Addresses potential problems before they occur. This involves analyzing trends, data, and risk assessments to eliminate potential causes of future nonconformances.
FDA 21 CFR 820.100 requirements:
The FDA's Quality System Regulation (QSR) mandates CAPA procedures that include:
- Analyzing processes, work operations, complaints, quality data, and service records
- Investigating causes of nonconformances
- Identifying actions needed to correct and prevent recurrence
- Verifying or validating the corrective and preventive actions
- Ensuring that information related to quality problems or nonconformances is disseminated to those directly responsible
- Submitting relevant information on identified quality problems and corrective actions to management review
- Documenting all CAPA activities
ISO 13485 CAPA requirements:
ISO 13485:2016 separates corrective action (Clause 8.5.2) and preventive action (Clause 8.5.3), requiring organizations to:
- Review nonconformities including customer complaints
- Determine causes of nonconformities
- Evaluate the need for actions
- Implement actions needed
- Review the effectiveness of corrective actions taken
- Update risk management documentation
CAPA process steps:
1. Identify - Detection of actual or potential problems through various sources
2. Investigate - Gather data, facts, and evidence related to the problem
3. Root Cause Analysis - Use tools like 5 Whys, Fishbone diagrams, or Failure Mode Effects Analysis (FMEA) to identify true underlying causes
4. Implement - Develop and execute action plans to address root causes
5. Verify Effectiveness - Confirm that implemented actions resolved the problem and prevented recurrence
6. Document - Maintain comprehensive records throughout the process
Common triggers for CAPA:
- Customer complaints and returns
- Internal audit findings
- Regulatory inspection observations (FDA 483s, warning letters)
- Nonconforming products or processes
- Management review findings
- Supplier quality issues
- Post-market surveillance data (adverse events, field actions)
- Process monitoring trends
- Employee suggestions
Documentation requirements:
Complete CAPA documentation must include:
- Problem description and source
- Investigation findings and data analysis
- Root cause determination methodology and results
- Proposed corrective/preventive actions with justification
- Implementation plan with responsibilities and timelines
- Effectiveness verification methods and results
- Closure approval and date
Metrics and trending:
Effective CAPA systems track key performance indicators:
- Number of CAPAs opened/closed per period
- Average time to close CAPAs
- CAPA effectiveness rate (% that prevent recurrence)
- CAPAs by source (complaints, audits, etc.)
- CAPAs by product line or process area
- Overdue CAPA aging
- Root cause categories for trend analysis
A well-implemented CAPA system demonstrates regulatory compliance, reduces product defects, minimizes customer complaints, and drives continuous improvement in medical device organizations.
Related Terms
More Compliance & Standards
View all미국 의료기기 제조업체에 대한 현행 우수 제조 관리 기준(cGMP) 요구사항을 규정하는 FDA의 품질 시스템 규정(QSR).
품질 활동 및 결과가 계획된 약정을 준수하는지 여부와 이러한 약정이 효과적으로 구현되고 있는지 확인하기 위한 품질 관리 시스템의 체계적이고 독립적인 검사.
유럽경제지역에서 판매되는 의료기기에 필수인 적합성 표시로, EU 보건, 안전 및 환경 요건 준수를 나타냄.
의료기기 설계를 제어하여 사용자 요구사항과 의도된 용도를 충족하도록 보장하는 21 CFR 820.30에 따른 FDA 요구사항입니다.
Need Help with Global Registration?