The pacemaker has the function of resynchronizing the heart and is compatible with MRI - Vietnam Registration 2402754ĐKLH/BYT-HTTB
Access comprehensive regulatory information for The pacemaker has the function of resynchronizing the heart and is compatible with MRI in Vietnam's medical device market through Pure Global AI's free database. This Risk Class TTBYT Loại D medical device is registered under number 2402754ĐKLH/BYT-HTTB and manufactured by Medtronic Plc. The authorized representative in Vietnam is CÔNG TY TNHH MEDTRONIC VIỆT NAM.
This page provides complete technical specifications, regulatory compliance details. Pure Global AI offers free access to 300,000+ Vietnamese medical device registrations, helping global MedTech companies navigate Vietnam MOH regulations, identify competitors, and discover partnership opportunities efficiently.
Device Details
Registration Details
2402754ĐKLH/BYT-HTTB
000.00.04.G18-210603-0004
Theo theo phụ lục
Theo phụ lục
Technical Details
The intended purpose The cardiac resynchronization therapy defibrillator (CRT-D) is a surgically implanted device designed to be used for an extended period of time to monitor and regulate the heart rhythm of the patient. These devices receive the intrinsic electrical activity through the cardiac leads' electrodes, analyze the heart rhythm based on the programmed sensing parameters, and perform resynchronization therapies to treat the condition of chronic heart failure and heart block. Indications The Solara Quad CRT-P MRI SureScan Model W4TR06/ Solara CRT-P MRI SureScan Model W1TR06 system is indicated for use in patients with heart failure and one or more of the following conditions: • Abnormality of the heart's electrical conduction with a prolonged QRS interval • Reduced ejection fraction (EF), regardless of the degree, as defined by the New York Heart Association (NYHA), and who are indicated for ventricular resynchronization and have a high degree of atrioventricular (AV) block • Reduced EF and who have all of the following: – A history of having a conventional pacemaker or ICD implanted previously – A worsening of heart failure despite optimal medical therapy – A high rate of RV resynchronization Frequency-adaptive resynchronization therapy is performed in patients who may benefit from the increased frequency response capability when increased exercise is performed The atrial and dual-chamber monitoring modes are indicated for patients who may benefit from maintaining AV synchrony.
Dates and Status
Oct 02, 2024