Endoscope Retraction Tool for Intravascular Ultrasound - Vietnam Registration 240000476/PCBA-HCM

Access comprehensive regulatory information for Endoscope Retraction Tool for Intravascular Ultrasound in Vietnam's medical device market through Pure Global AI's free database. This Risk Class TTBYT Loại A medical device is registered under number 240000476/PCBA-HCM and manufactured by Boston Scientific Corporation. The authorized representative in Vietnam is CÔNG TY TNHH BOSTON SCIENTIFIC VIỆT NAM.

This page provides complete technical specifications, regulatory compliance details. Pure Global AI offers free access to 300,000+ Vietnamese medical device registrations, helping global MedTech companies navigate Vietnam MOH regulations, identify competitors, and discover partnership opportunities efficiently.

Free Database
Powered by Pure Global AI
300,000+ Devices
240000476/PCBA-HCM
Registration Details
Vietnam MOH Registration: 240000476/PCBA-HCM
Pure Global
DJ Fang

DJ Fang

MedTech Regulatory Expert

Need help with 30+ markets registration?

Pricing

Device Details

Endoscope Retraction Tool for Intravascular Ultrasound
VN: Dụng cụ kéo đầu dò dùng cho máy siêu âm lòng mạch
Risk Class TTBYT Loại A

Registration Details

240000476/PCBA-HCM

000.00.19.H29-240311-0014

Permanent Sled

H749393160100

Company Information

UNITED STATES

Boston Scientific

Technical Details

The pullback catheter combined with the IVUS system and the Motordrive control unit operates as a system and is indicated for patients undergoing interventional procedures in the coronary arteries, such as angioplasty and stent placement. The automatic pullback catheter is designed to be used when: • The user wants to standardize the method of acquiring and recording IVUS images; this may vary from case to case and from user to user; • The user wants to determine the linear distance, randomly, post-procedurally. This requires the lumen of the intravascular ultrasound catheter of the BSC to be pulled back at a known and uniform speed. The action is mechanized, thus much more uniform than manual manipulation; • The user wants to create 2D cross-sectional reconstructions along the length from a series of 2D ultrasound images. The images must be acquired at a uniform speed (consecutive frames) to be able to be reconstructed; • The use of the pullback catheter is intended to automatically reverse the lumen image CHI of the intravascular ultrasound catheter of the BSC compatible. The device is not intended to advance the catheter or the lumen image of the catheter by means of the motor and will not operate in this way.

Dates and Status

Mar 27, 2024