Pure Global

Laser Unit-Laser units are used to provide laser radiation for cutting, coagulation, vaporization and ablation of biological tissue, as well as for lithotripsy of stones during surgical interventions. Laser units do not come into contact with the body.,forceps - India CDSCO Medical Device Registration

Laser Unit-Laser units are used to provide laser radiation for cutting, coagulation, vaporization and ablation of biological tissue, as well as for lithotripsy of stones during surgical interventions. Laser units do not come into contact with the body.,forceps is a medical device registered with India's Central Drugs Standard Control Organization (CDSCO) under UID IMP/MD/2023/000244_e276a39aadad4a7a02864da9a4227134_39ea438f0d8afe8b4960be34cfc30462. This device is marketed under the brand name Not Applicable. The license holder is KARL STORZ ENDOSCOPY INDIA PRIVATE LIMITED, and it is classified as Device Class Class C. The approving authority is CDSCO.

This page provides comprehensive regulatory information including complete registration details, license holder information, device classification, and related products. Pure Global AI offers free access to 71,807+ India medical device registrations, helping global MedTech companies identify partners, analyze markets, and discover business opportunities efficiently.

Free Database
Powered by Pure Global AI
CDSCO Registered
Class Class C
Laser Unit-Laser units are used to provide laser radiation for cutting, coagulation, vaporization and ablation of biological tissue, as well as for lithotripsy of stones during surgical interventions. Laser units do not come into contact with the body.,forceps
UID: IMP/MD/2023/000244_e276a39aadad4a7a02864da9a4227134_39ea438f0d8afe8b4960be34cfc30462

Brand Name

Not Applicable

Device Class

Class C

Approving Authority

CDSCO

Product Information

The biopsy and grasping forceps are used to remove or grasp tissue in fetoscopy. The biopsy and grasping forceps are designed for transient use in surgically invasive interventions. Take Apart forceps with double sheath for bipolar coagulation are used for grasping and bipolar coagulation of tissue during endoscopic interventions. HF-forceps inserts are intended for grasping, preparation, dissection, and, if necessary, coagulation of tissue during minimally invasive interventions. HF-forceps are surgically invasive and meant for short term use.,needLe-Coagulation or dissecting electrodes or dissecting needles are used for coagulation and dissection in surgical laparoscopy, gynecology, and urology as well as surgical thoracoscopy and transanal interventions. Coagulation or dissecting electrodes or dissecting needles are designed for transient use in surgically invasive interventions. Surgical instrument for unipolar or bipolar coagulation and dissection (Not Applicable) during laparoscopy and/or laparoscopic surgery in gynecology The coagulation instrument is used to coagulate in ENT and skull base surgery. The models with a suction connection are used as suction tubes for simultaneously suctioning irrigation fluid, tissue, and bodily fluid. Coagulation instruments are designed for transient use in surgically invasive interventions.,cannuLa-A suction and coagulation cannula is used for suctioning liquid or secretions from the surgical field or for coagulation. Coagulation suction and irrigation tubes are intended for suction irrigation and coagulation in thoracic surgery. Coagulation suction and irrigation tubes are surgically invasive and meant for transient use. Coagulation suction and irrigation tubes are used in combination with a handle for the irrigation and/or suctioning of fluids and for coagulation in colorectal surgery. Coagulation suction and irrigation tubes are designed for transient use in surgically invasive interventions. Suction and coagulation cannulae are designed for suctioning and hemostasis using high-frequency current in bronchoscopy and esophagoscopy. Suction and coagulation cannulae are designed for transient use in surgically invasive interventions. Suction and irrigation coagulation cannulas are intended for use in connection with a handle for the suction irrigation and possibly the coagulation and preparation of tissue in laparoscopic surgery, gynecology, urology and thoracoscopy, in transanal interventions, in oral and maxillofacial surgery and in plastic surgery. Suction and irrigation coagulation cannulas are designed for temporary use in surgical invasive interventions. The instruments for monopolar coagulation are intended as accessories for HF equipment serving both as an electrode for monopolar coagulation and simultaneously as a suction tube for the extraction of fluid on models with a suction device connection. They must only be used by suitably trained and qualified technical staff. The bipolar suction devices are intended as an accessory to HF equipment for the suctioning of blood and secretions with the added possibility of the bipolar coagulation of tissue and vessels in the paranasal sinus region. They must only be used by suitably trained technical staff.

Pure Global
DJ Fang

DJ Fang

MedTech Regulatory Expert

Need help with 30+ markets registration?

Pricing