Pure Global

KniFe-Tendon knives and separators are used for the surgical separation of soft tissue, in particular the quadriceps tendon or similar ligament structures in arthroscopy and minimally invasive orthopedics. Tendon knives and separators are designed for transient use in surgically invasive interventions.,retractor-Retractors are used to distend the examination and operating field as well as to hold open and hold back skin, tissue, and cartilage during cochlear implantation surgery. Retractors are designed for transient use in surgically invasive interventions. Instruments for cochlear implantation surgery must not be used for interventions in direct contact with the central nervous system and central cardiovascular system. Retractors are used to keep tissue and organs away from the operating field. In addition, a retractor can be used to grasp tissue during laparoscopic surgery, gynecology, urology, and thoracoscopy. Retractors are designed for short-term use in surgically invasive interventions.,insert-Sponge holder inserts are intended for holding swabs during minimally invasive interventions. Sponge holder inserts are surgically invasive and meant for transient use. The obturator is used for atraumatically introducing a cystoscope or resectoscope sheath into the prostate or bladder via the urethra, hence creating access to these organs. The visual obturator is also used for optical visualization of the urethra while introducing the sheath. The examination/working insert is used for connecting the telescope and sheath and for visualizing the organ being examined. It makes it possible to insert auxiliary instruments via the endoscope . Obturators/visual obturators/instrument inlets are designed for transient use in invasive interventions through a body orifice. Uterine manipulators are intended to manipulate and stabilize the uterus and adnexa during diagnostic and therapeutic interventions within the scope of laparoscopic gynaecology. Uterine manipulators are surgically invasive and meant for short term use.,probe-Navigable probes are used as a guide in, probing and dilating excretory ducts and body cavities during interventions in ENT medicine and skull base surgery. Navigable probes are surgically invasive and designed for transient use. The fiber optic ureter probe is inserted transurethrally into the ureter and is used to illuminate the ureter for better visualization during laparoscopic interventions. Fiber optic ureter probes are designed for short-term use in invasive interventions through a body orifice and surgically invasive interventions. The working element is used to manipulate an instrument by hand movement during transurethral laser intervention in the urethra, prostate or bladder. The working element is inserted and used via the sheath. Working elements are designed for short-term use in invasive interventions through a body orifice.,working element - India CDSCO Medical Device Registration

KniFe-Tendon knives and separators are used for the surgical separation of soft tissue, in particular the quadriceps tendon or similar ligament structures in arthroscopy and minimally invasive orthopedics. Tendon knives and separators are designed for transient use in surgically invasive interventions.,retractor-Retractors are used to distend the examination and operating field as well as to hold open and hold back skin, tissue, and cartilage during cochlear implantation surgery. Retractors are designed for transient use in surgically invasive interventions. Instruments for cochlear implantation surgery must not be used for interventions in direct contact with the central nervous system and central cardiovascular system. Retractors are used to keep tissue and organs away from the operating field. In addition, a retractor can be used to grasp tissue during laparoscopic surgery, gynecology, urology, and thoracoscopy. Retractors are designed for short-term use in surgically invasive interventions.,insert-Sponge holder inserts are intended for holding swabs during minimally invasive interventions. Sponge holder inserts are surgically invasive and meant for transient use. The obturator is used for atraumatically introducing a cystoscope or resectoscope sheath into the prostate or bladder via the urethra, hence creating access to these organs. The visual obturator is also used for optical visualization of the urethra while introducing the sheath. The examination/working insert is used for connecting the telescope and sheath and for visualizing the organ being examined. It makes it possible to insert auxiliary instruments via the endoscope . Obturators/visual obturators/instrument inlets are designed for transient use in invasive interventions through a body orifice. Uterine manipulators are intended to manipulate and stabilize the uterus and adnexa during diagnostic and therapeutic interventions within the scope of laparoscopic gynaecology. Uterine manipulators are surgically invasive and meant for short term use.,probe-Navigable probes are used as a guide in, probing and dilating excretory ducts and body cavities during interventions in ENT medicine and skull base surgery. Navigable probes are surgically invasive and designed for transient use. The fiber optic ureter probe is inserted transurethrally into the ureter and is used to illuminate the ureter for better visualization during laparoscopic interventions. Fiber optic ureter probes are designed for short-term use in invasive interventions through a body orifice and surgically invasive interventions. The working element is used to manipulate an instrument by hand movement during transurethral laser intervention in the urethra, prostate or bladder. The working element is inserted and used via the sheath. Working elements are designed for short-term use in invasive interventions through a body orifice.,working element is a medical device registered with India's Central Drugs Standard Control Organization (CDSCO) under UID IMP/MD/2023/000244_886e28cee9f7cea4bc1af0ce2b0f9ef9_a6f1ec5215f763d1c5f567333ed746b0. This device is marketed under the brand name telescope. The license holder is KARL STORZ ENDOSCOPY INDIA PRIVATE LIMITED, and it is classified as Device Class Class B. The approving authority is CDSCO.

This page provides comprehensive regulatory information including complete registration details, license holder information, device classification, and related products. Pure Global AI offers free access to 71,807+ India medical device registrations, helping global MedTech companies identify partners, analyze markets, and discover business opportunities efficiently.

Free Database
Powered by Pure Global AI
CDSCO Registered
Class Class B
KniFe-Tendon knives and separators are used for the surgical separation of soft tissue, in particular the quadriceps tendon or similar ligament structures in arthroscopy and minimally invasive orthopedics. Tendon knives and separators are designed for transient use in surgically invasive interventions.,retractor-Retractors are used to distend the examination and operating field as well as to hold open and hold back skin, tissue, and cartilage during cochlear implantation surgery. Retractors are designed for transient use in surgically invasive interventions. Instruments for cochlear implantation surgery must not be used for interventions in direct contact with the central nervous system and central cardiovascular system. Retractors are used to keep tissue and organs away from the operating field. In addition, a retractor can be used to grasp tissue during laparoscopic surgery, gynecology, urology, and thoracoscopy. Retractors are designed for short-term use in surgically invasive interventions.,insert-Sponge holder inserts are intended for holding swabs during minimally invasive interventions. Sponge holder inserts are surgically invasive and meant for transient use. The obturator is used for atraumatically introducing a cystoscope or resectoscope sheath into the prostate or bladder via the urethra, hence creating access to these organs. The visual obturator is also used for optical visualization of the urethra while introducing the sheath. The examination/working insert is used for connecting the telescope and sheath and for visualizing the organ being examined. It makes it possible to insert auxiliary instruments via the endoscope . Obturators/visual obturators/instrument inlets are designed for transient use in invasive interventions through a body orifice. Uterine manipulators are intended to manipulate and stabilize the uterus and adnexa during diagnostic and therapeutic interventions within the scope of laparoscopic gynaecology. Uterine manipulators are surgically invasive and meant for short term use.,probe-Navigable probes are used as a guide in, probing and dilating excretory ducts and body cavities during interventions in ENT medicine and skull base surgery. Navigable probes are surgically invasive and designed for transient use. The fiber optic ureter probe is inserted transurethrally into the ureter and is used to illuminate the ureter for better visualization during laparoscopic interventions. Fiber optic ureter probes are designed for short-term use in invasive interventions through a body orifice and surgically invasive interventions. The working element is used to manipulate an instrument by hand movement during transurethral laser intervention in the urethra, prostate or bladder. The working element is inserted and used via the sheath. Working elements are designed for short-term use in invasive interventions through a body orifice.,working element
UID: IMP/MD/2023/000244_886e28cee9f7cea4bc1af0ce2b0f9ef9_a6f1ec5215f763d1c5f567333ed746b0

Brand Name

telescope

Device Class

Class B

Approving Authority

CDSCO

Product Information

The working element is used to manipulate an instrument (telescope) by hand movement during transurethral laser intervention in the urethra, prostate or bladder. The working element is inserted and used via the sheath. Working elements are designed for short-term use in invasive interventions through a body orifice. Working elements are intended for manipulation of an instrument by hand movement in the lower urinary tract. Working elements are surgically invasive and meant for short term use. Working elements are intended for moving instruments in gynecological applications. Working elements are not invasive or invasive (telescope) and meant for short term use. The working element is used to manipulate an instrument (telescope) by moving the hand during the intrauterine intervention. Working elements are intended for short-term use in surgically invasive interventions