Pure Global

Cardiac Resynchronization Therapy-Pacemaker - India CDSCO Medical Device Registration

Cardiac Resynchronization Therapy-Pacemaker is a medical device registered with India's Central Drugs Standard Control Organization (CDSCO) under UID IMP/MD/2021/000201_c30b10b9bb19a09a9dde03a6324a82e8_4d647fbd46ebb5f92c96e541e9981e5b. This device is marketed under the brand name Endurity Core. The license holder is M/s St. Jude Medical India Pvt. Ltd, and it is classified as Device Class Class D. The approving authority is CDSCO.

This page provides comprehensive regulatory information including complete registration details, license holder information, device classification, and related products. Pure Global AI offers free access to 71,807+ India medical device registrations, helping global MedTech companies identify partners, analyze markets, and discover business opportunities efficiently.

Free Database
Powered by Pure Global AI
CDSCO Registered
Class Class D
Cardiac Resynchronization Therapy-Pacemaker
UID: IMP/MD/2021/000201_c30b10b9bb19a09a9dde03a6324a82e8_4d647fbd46ebb5f92c96e541e9981e5b

Brand Name

Endurity Core

Device Class

Class D

Approving Authority

CDSCO

Product Information

Implantation of a single-chamber pulse generator, dual-chamber pulse generator, or CRT-P (Endurity Core) is indicated in one or more of the following permanent conditions or any combination of these symptoms: Syncope Presyncope Fatigue Disorientation due to arrhythmia or bradycardia Implantation of a CRT-P is indicated for patients who: Would benefit from resynchronization of the right and left ventricles. Have one or more conventional indications for the implantation of a pacemaker. MR Conditional pulse generator is conditionally safe for use in the MRI environment when used in a complete MR Conditional pacing system and according to the instructions in the MRI-Ready System manual for the St. Jude Medical™ MR Conditional Pacing System. Rate-modulated pacing is indicated for patients with chronotropic incompetence, and for those who would benefit from increased stimulation rates concurrent with physical activity. Dual-chamber pacing (Endurity Core) is indicated for those patients exhibiting: Sick sinus syndrome Chronic, symptomatic second- and third-degree AV block Recurrent Adams-Stokes syndrome Symptomatic bilateral bundle branch block when tachyarrhythmia and other causes have been ruled out Atrial pacing is indicated for patients with sinus node dysfunction and normal AV and intraventricular conduction systems. Ventricular pacing is indicated for patients with significant bradycardia and: Normal sinus rhythm with only rare episodes of AV block or sinus arrest Chronic atrial fibrillation (Endurity Core) Severe physical disability AF Suppression™ pacing (Endurity Core) is indicated for suppression of paroxysmal or persistent atrial fibrillation episodes in patients with one or more of the above pacing indications. AT/AF Detection Algorithm. The AT/AF detection algorithm is indicated for detecting atrial tachyarrhythmias which have been found to be associated with an increased risk of stroke in elderly, hypertensive, pacemaker patients without prior history of AF. For specific indications associated with individual modes, refer to the programmer's on-screen help