SiMD
Software in a Medical Device
SiMD (Software in a Medical Device) is software that is integral to a hardware medical device and cannot function independently from the device.
Complete Guide to SiMD
Software in a Medical Device (SiMD) is software that is embedded within or an integral part of a hardware medical device. Unlike Software as a Medical Device (SaMD), SiMD cannot function independently and is designed specifically to control, drive, or support the operation of a particular medical device.
Key characteristics of SiMD:
- Embedded within hardware medical device
- Cannot function independently from the device
- Controls device operations or functions
- Part of overall device system architecture
- Subject to same regulatory classification as the device
- Integral to device's intended use
SiMD vs. SaMD - Critical differences:
SiMD (Software IN a Medical Device):
- Embedded in hardware device
- Cannot be used standalone
- Examples: pacemaker software, imaging device software, infusion pump controller
- Regulated as part of the overall device
- Device classification determines regulatory pathway
SaMD (Software AS a Medical Device):
- Standalone software with medical purpose
- Can run on general computing platforms
- Examples: mobile diagnostic apps, clinical decision support systems
- Regulated as a medical device itself
- IMDRF SaMD classification framework applies
Common examples of SiMD:
Cardiovascular devices:
- Pacemaker control algorithms and sensing software
- Defibrillator rhythm analysis and shock delivery software
- Heart-lung machine control and monitoring systems
- Blood pressure monitor measurement algorithms
Imaging and diagnostic equipment:
- MRI scanner image acquisition and reconstruction software
- CT scanner control and image processing software
- Ultrasound imaging algorithms and measurement tools
- X-ray equipment exposure control and image enhancement
Therapeutic devices:
- Radiation therapy planning and delivery control software
- Surgical robot control systems and safety algorithms
- Infusion pump dose calculation and delivery software
- Ventilator breath control and alarm algorithms
Laboratory and IVD devices:
- Clinical chemistry analyzer control and calculation software
- Blood gas analyzer measurement algorithms
- Hematology analyzer cell counting and classification software
- Genetic sequencer data acquisition and base calling software
Regulatory considerations for SiMD:
IEC 62304 - Medical Device Software Lifecycle:
SiMD must comply with IEC 62304, which defines software development lifecycle processes including:
- Software development planning and requirements
- Software architectural and detailed design
- Software unit implementation and verification
- Software integration and testing
- Software release and maintenance
- Software risk management throughout lifecycle
- Configuration management and problem resolution
Software safety classification (IEC 62304):
Based on potential harm to patient if software fails:
- Class A - No injury or damage to health possible
- Class B - Non-serious injury possible
- Class C - Death or serious injury possible
Higher safety classes require more rigorous development processes, documentation, and testing.
Integration with device risk management:
SiMD risk analysis must be integrated with overall device risk management per ISO 14971:
- Identify software-related hazards (algorithm errors, timing failures, data corruption)
- Assess risks considering software failure modes
- Implement software risk controls (validation, error handling, redundancy)
- Verify effectiveness of risk controls through testing
- Document residual risks in risk management file
Software verification and validation:
Verification activities:
- Unit testing of software modules
- Integration testing of software components
- Software system testing against specifications
- Code reviews and static analysis
- Coverage analysis (statement, branch, path coverage)
Validation activities:
- Testing under actual or simulated use conditions
- Validation with representative hardware
- Worst-case and boundary condition testing
- User interface and usability validation
- Performance validation (timing, accuracy, reliability)
Documentation requirements:
Software-specific documentation:
- Software requirements specification (SRS)
- Software architecture design
- Software detailed design
- Software development and test plans
- Software verification and validation reports
- Software risk analysis
- Software version control and configuration management
- Known anomalies and software maintenance history
Integration with device documentation:
- Software description in Design History File (DHF)
- Software hazard analysis in risk management file
- Software validation in overall device validation
- Software version in device labeling and IFU
- Software updates and changes in change control records
Cybersecurity considerations for SiMD:
FDA Cybersecurity Guidance:
SiMD that connects to networks or receives updates must address:
- Threat modeling and vulnerability assessment
- Secure software architecture and coding practices
- Authentication and authorization controls
- Data encryption for stored and transmitted data
- Secure software update mechanisms
- Logging and monitoring capabilities
- Incident response procedures
Software Bill of Materials (SBOM):
FDA increasingly expects manufacturers to maintain SBOM for SiMD:
- Inventory of software components
- Open-source and third-party libraries
- Version tracking and vulnerability management
- Supply chain transparency
SOUP - Software of Unknown Provenance:
Off-the-shelf software components used in SiMD:
- Operating systems (real-time OS, embedded Linux)
- Third-party libraries and frameworks
- Open-source components
- Requires qualification testing per IEC 62304
- Risk analysis for SOUP failures
- Plan for SOUP updates and obsolescence
Software updates and changes:
Software as sole change:
If only software changes (hardware unchanged):
- May require new regulatory submission (510(k), CE marking update)
- Assess impact on device safety and effectiveness
- Conduct regression testing
- Update labeling with new software version
Continuous software updates:
For devices with frequent software updates:
- Establish software change control procedures
- Define criteria for major vs. minor changes
- Determine which changes require regulatory notification
- Implement automated testing for rapid validation
- Consider Predetermined Change Control Plan (PCCP) for FDA
Agile development for SiMD:
IEC 62304 compatible with Agile methodologies:
- Iterative development with continuous verification
- Sprint-based design review and testing
- Automated regression testing
- Risk-based documentation approach
- Traceability maintained throughout sprints
Interoperability and device integration:
Networked SiMD:
Software that communicates with other systems:
- HL7, FHIR for healthcare data exchange
- DICOM for medical imaging
- Bluetooth, Wi-Fi, cellular connectivity
- Requires interoperability testing
- Cybersecurity risks from network exposure
Medical device interoperability:
- Integration with Electronic Health Records (EHR)
- Connection to hospital information systems
- Data exchange with other medical devices
- Adherence to interoperability standards
- Validation of data integrity across systems
Post-market software performance:
Post-Market Surveillance (PMS):
- Monitor software-related complaints and incidents
- Track software failure modes and error reports
- Analyze software performance metrics
- Identify emerging software risks or bugs
- Collect user feedback on software usability
Software maintenance:
- Corrective maintenance (bug fixes)
- Adaptive maintenance (OS updates, platform changes)
- Perfective maintenance (performance improvements)
- Preventive maintenance (refactoring, technical debt)
Vigilance reporting for software:
Report serious incidents related to software:
- Software bugs causing patient harm
- Algorithm errors leading to misdiagnosis or wrong therapy
- Software failures causing device malfunction
- Cybersecurity incidents compromising patient data or safety
International regulatory perspectives:
FDA (USA):
- Software documentation required in 510(k), PMA submissions
- Software level of concern (minor, moderate, major)
- Cybersecurity expectations for networked devices
- Off-The-Shelf Software guidance for SOUP
EU MDR:
- SiMD subject to same classification as device
- IEC 62304 compliance expected
- Software version in UDI-DI (Device Identifier)
- Cybersecurity addressed in General Safety and Performance Requirements
Canada Health Canada:
- Guidance on software in medical devices
- IEC 62304 referenced in regulatory submissions
- Software changes may require license amendment
NMPA (China):
- Software registration requirements
- Software description and architecture documentation
- Cybersecurity assessment for networked devices
- Software testing and validation reports
Best practices for SiMD development:
Plan software development:
- Define software requirements early in device design
- Establish software development plan per IEC 62304
- Allocate adequate resources and expertise
- Choose appropriate development tools and platforms
Implement robust software engineering:
- Follow secure coding practices (CERT, MISRA)
- Use version control systems (Git, SVN)
- Implement automated testing and continuous integration
- Conduct code reviews and static analysis
- Maintain traceability from requirements to tests
Integrate software risk management:
- Conduct software hazard analysis
- Implement software risk controls (error handling, alarms, limits)
- Validate risk control effectiveness
- Update risk analysis when software changes
Validate thoroughly:
- Test software in target hardware environment
- Include worst-case and stress testing
- Validate with clinical or simulated use scenarios
- Conduct usability testing with representative users
- Document all validation activities and results
Maintain comprehensive documentation:
- Keep Design History File organized and complete
- Document rationale for design decisions
- Maintain software development and test records
- Update documentation for all software changes
Plan for lifecycle maintenance:
- Establish software maintenance procedures
- Monitor software performance post-market
- Plan for software updates and cybersecurity patches
- Prepare for platform obsolescence
- Define end-of-support strategy
SiMD is a critical component of modern medical devices, and proper software development, validation, and maintenance are essential for ensuring patient safety and regulatory compliance. The increasing complexity of medical device software demands rigorous engineering practices and adherence to international standards like IEC 62304.
Related Terms
More Device Classification
View allMedical devices that incorporate artificial intelligence or machine learning algorithms to analyze data, support clinical decisions, or perform diagnostic functions.
A risk-based system for categorizing medical devices that determines the level of regulatory control and the pathway to market authorization.
A medical device used to examine specimens from the human body to provide information for diagnosis, monitoring, or screening purposes.