IVD Department for Blood Type Determination - Vietnam Registration 240002324/PCBA-HN

Access comprehensive regulatory information for IVD Department for Blood Type Determination in Vietnam's medical device market through Pure Global AI's free database. This Risk Class TBYT Loại A medical device is registered under number 240002324/PCBA-HN and manufactured by Sanquin Reagents B.V.. The authorized representative in Vietnam is CÔNG TY TNHH VẠN NIÊN.

This page provides complete technical specifications, regulatory compliance details. Pure Global AI offers free access to 300,000+ Vietnamese medical device registrations, helping global MedTech companies navigate Vietnam MOH regulations, identify competitors, and discover partnership opportunities efficiently.

Free Database
Powered by Pure Global AI
300,000+ Devices
240002324/PCBA-HN
Registration Details
Vietnam MOH Registration: 240002324/PCBA-HN
Pure Global
DJ Fang

DJ Fang

MedTech Regulatory Expert

Need help with 30+ markets registration?

Pricing

Device Details

IVD Department for Blood Type Determination
VN: Bộ IVD xét nghiệm định nhóm máu
Risk Class TBYT Loại A

Registration Details

240002324/PCBA-HN

000.00.19.H26-241020-0001

Theo theo phụ lục

Theo phụ lục

Company Information

Theo theo phụ lục

Sanquin Reagents B.V.

Technical Details

1. PeliControl (K1379) are whole blood samples that can be used as patient samples for quality control processes (internal control) for the following tests: ABO/Rh-D blood group determination, detection of abnormal antibodies and hemolytic reactions. 2. Cellbind direct type (K7012) is a column test to determine the blood group antigens on red blood cells, including red blood cells coated in vivo with the component antibodies and/or complement. 3. Cellbind LISS (K7110, 7130) is an in vitro diagnostic medical device for laboratory specialists, used to dilute red blood cells from EDTA blood samples into 0.5% suspension, which can be tested manually on the Cellbind column test card or in an automated analyzer. 4. Cellbind P3 (K7210), Cellbind ID16 (K7230) are 0.5% cell suspension for screening and identification of red blood cell antibodies in human serum and plasma. 5. Cellbind A1 reagent red cells (K7240), Cellbind B reagent red cells (K7242): These 0.5% cell suspensions are recommended for use in the Cellbind Screen card (see the K7000 User Manual) to detect anti-A and anti-B antibodies (A1 and B test cells) in human serum or plasma and are used as positive and negative controls (O positive cells and A2 test cells). 6. Stirrer Balls (K7390) are stirrer balls used in the blood group determination test, to prevent the aggregation of red blood cells in the test. 7. Pelikloon anti-E (lgM) monoclonal (K1191, K1204), Pelikloon anti-C (IgM) monoclonal (K1195, K1202), Pelikloon anti-c (IgM) monoclonal (K1196, K1203), Pelikloon anti-e (IgM) monoclonal (K1197, K1205): Blood group reagents to detect the Rh E, C, c, or e antigens on human red blood cells. 8. Pelikloon anti-K (IgM) monoclonal (K1199): Blood group reagents to detect the Kell (K) antigen on human red blood cells. 9. Cellbind Workstation (K7301): The Cellbind sample tray, where the reaction takes place. 10. Cellbind Centrifuge (12 cards) (K7312): The Cellbind centrifuge, pre-programmed to work with the Cellbind column test cards. 11. Cellbind incubator (K7314): The Cellbind incubator, used to incubate the Cellbind column test cards. 12. Cellbind DILUENT (K7180): The LISS buffer solution for the Cellbind column test cards, the diluent medium to prepare the 0.5% red blood cell suspension from Sanquin 3% red blood cells or Sanquin red blood cell suspension (100 ml).

Dates and Status

Oct 23, 2024