Ventana VENTANA CLDN18 (43-14A) RxDx Assay - HSA Registration DE0510669

Access comprehensive regulatory information for Ventana VENTANA CLDN18 (43-14A) RxDx Assay in the Singapore medical device market through Pure Global AI's free database. This CLASS C IVD medical device is registered under HSA registration number DE0510669 and owned by Ventana Medical Systems, Inc.. The device was registered on May 02, 2025.

This page provides complete registration details including product owner information, registrant details, importer information, and regulatory compliance data from the official Singapore HSA medical device database. Pure Global AI offers free access to Singapore's complete medical device registry, helping global MedTech companies navigate HSA regulations efficiently.

Free Database
Powered by Pure Global AI
HSA Official Data
CLASS C IVD
DE0510669
Ventana VENTANA CLDN18 (43-14A) RxDx Assay
HSA Registration Number: DE0510669
Pure Global
DJ Fang

DJ Fang

MedTech Regulatory Expert

Need help with 30+ markets registration?

Pricing
Product Description

VENTANA CLDN18 (43-14A) RxDx Assay is a qualitative IHC assay using mouse monoclonal anti-claudin 18, clone 43-14A, intended for laboratory use in the assessment of claudin 18 (CLDN18) protein in FFPE gastric adenocarcinoma including gastroesophageal junction (GEJ) tissue specimens by light microscopy. This assay is used with OptiView DAB IHC Detection Kit for staining on a BenchMark IHC/ISH instrument. The assay is indicated as an aid in identifying patients with gastric or GEJ adenocarcinoma who may be eligible for treatment with VYLOYโ„ข (zolbetuximab) in accordance with the approved therapeutic product labeling. The clinical cutoff is โ‰ฅ75% tumor cells (%TC) demonstrating moderate to strong membrane CLDN18 staining above background. Test results of the VENTANA CLDN18 (43-14A) RxDx Assay should be interpreted by a qualified pathologist in conjunction with histological examination, relevant clinical information, and proper controls. This product is intended for IVD use.

Device Classification
Device Class
CLASS C IVD
Medical Speciality Area
Pathology
Registration Information
Registration Number
DE0510669
Registration Date
May 02, 2025
Retention Due Date
May 01, 2026
Product Owner
Short Name
Ventana Medical Systems, Inc.
Address
1910 East Innovation Park Drive, Tucson, AZ, 85755, UNITED STATES
Registrant
Address
8 KALLANG AVENUE, APERIA, #10-01/09, SINGAPORE 339509
Importer
Address
8 KALLANG AVENUE, APERIA, #10-01/09, SINGAPORE 339509
Model Information
Model Name(s)
VENTANA CLDN18 (43-14A) RxDx Assay Negative Control (Monoclonal)
Model Identifier(s)
744-7162 / 09620656001 760-2014 / 05266670001