Calcium (CA) detection kit (thymolphthalein complexone method)
- Device class
- Class II
- Model specifications
- Reagent 1: 90mL×6, Reagent 2: 90mL×2; Reagent 1: 90mL×3, Reagent 2: 90mL×1; Reagent 1: 90mL×3, Reagent 2: 45mL×2; Reagent 1: 60mL×5, Reagent 2: 20mL×5; Reagent 1: 60mL×2, Reagent 2: 20mL×2; Reagent 1: 60mL×1, Reagent 2: 20mL×1; Reagent 1: 60mL×3, Reagent 2: 60mL×1; Reagent 1: 15mL×1, Reagent 2: 5mL×1; Reagent 1: 300mL×1, Reagent 2: 100mL×1; Reagent 1: 3000mL × 1, Reagent 2: 1000mL×1; 400 servings (Reagent 1: 60mL×1, Reagent 2: 20mL×1); 2000 servings (reagent 1: 300mL×1, reagent 2: 100mL×1); Calibrator (optional): 1mL×1.试剂1:90mL×6,试剂2:90mL×2; 试剂1:90mL×3,试剂2:90mL×1; 试剂1:90mL×3,试剂2:45mL×2; 试剂1:60mL×5,试剂2:20mL×5; 试剂1:60mL×2,试剂2:20mL×2; 试剂1:60mL×1,试剂2:20mL×1; 试剂1:60mL×3,试剂2:60mL×1; 试剂1:15mL×1,试剂2:5mL×1; 试剂1:300mL×1,试剂2:100mL×1; 试剂1:3000mL×1,试剂2:1000mL×1; 400人份(试剂1:60mL×1,试剂2:20mL×1); 2000人份(试剂1:300mL×1,试剂2:100mL×1); 校准品(选配):1mL×1。
- Approval department
- Beijing Municipal Drug Administration北京市药品监督管理局
- Registration number
- 京械注准20222400294
- Approval date
- July 22, 2022
- Expiry date
- July 21, 2027
- Name
- Beijing Baiao Taikang Biotechnology Co., Ltd.北京安图生物工程有限公司
- Province/Region
- Beijing北京
- Address
- Building 17 and Building 18, No. 13 Mintai Road, Beiwu Town, Shunyi District, Beijing (Science and Technology Innovation Functional Area)北京市顺义区北务镇民泰路13号院17号楼、18号楼(科技创新功能区)
- Production address
- 北京市顺义区北务镇民泰路13号院17号楼、18号楼、24号楼(科技创新功能区)
For the quantitative determination of the concentration of calcium in human serum in vitro.
用于体外定量测定人血清中钙的浓度。
Component concentration Reagent 1 R1 ethanolamine ≥100mmol/L Reagent 2 R2 o-cresolphthalein complexing agent ≥0.1g/L calibrator (Optional) 1 level, liquid calcium ion Target concentration: 3mmol/L The calibrator is lot specific, and the specific values are detailed in the bottle label.
成 分 浓 度 试剂1 R1 乙醇胺 ≥100mmol/L 试剂2 R2 邻甲酚酞络合剂 ≥0.1g/L 校准品 (选配) 1水平,液体 钙离子 目标浓度:3mmol/L 校准品具有批特异性,具体定值详见瓶签。
2 °C ~ 8 °C sealed storage, the validity period is 18 months
2℃~8℃避光密封贮存,有效期为18个月
- Appendix
- 产品技术要求
Access comprehensive regulatory information for Calcium (CA) detection kit (thymolphthalein complexone method) in the China medical device market through Pure Global AI's free database. This Class II medical device is registered under NMPA registration number 京械注准20222400294 and owned by Beijing Baiao Taikang Biotechnology Co., Ltd.. The device was approved on July 22, 2022.
This page provides complete registration details including registrant information, province location (Beijing), intended use, and regulatory compliance data from the official China NMPA medical device database. Pure Global AI offers free access to China's complete medical device registry, helping global MedTech companies navigate NMPA regulations efficiently.